Product Home
Special Features
Models, Options, Accessories
Manuals
Technical Data
 
  Bench Instruments >> APPA 200 Series The most Friendly Bench Instruments
 
 Specifications  
 Voltage AC  
  APPA 201
  Range:                                   2.000V~600V
  Basic Accuracy:                 +/-(1.5%+5d)
  APPA 203
  Range:                                   4.000V~600V
  Basic Accuracy:                 +/-(0.8%+5d)
  APPA 205
  Range:                                   4.000V~600V
  Basic Accuracy:                 +/-(0.5%+5d)
  APPA 207
  Range:
                                   400.0mV~750V
  Basic Accuracy:                 +/-(0.7%+5d)

  APPA 201, 203
  Conversion Type:                Average sensing RMS indicating
  APPA 205
  Conversion Type:                True RMS reading on AC mode
  APPA 207
  Conversion Type:               (AC+DC) True RMS reading on AC mode
                                                  ACV spec. +1.00%+8d

  Input Impedance:               10M?//100pF
    
  APPA 201
  Frequency Resonse:
         40Hz~500Hz
  APPA 203, 205
  Frequency Response:      
40Hz~1kHz
  APPA 207
  Frequency Response:
       40Hz~100kHz

  APPA 201, 203, 205
  Overload Protection:
         600V DC or 600V rms
  APPA 207
  Overload Protection:         1000V DC or 750V rms

 Voltage DC
  APPA 201
  Range:                                   200.0mV~600V
  Basic Accuracy:                 +/-(0.5%+2d)
  APPA 203
  Range:                                   400.0mV~600V
  Basic Accuracy:                 +/-(04%+2d)
  APPA 205
  Range:                                   400.0mV~600V
  Basic Accuracy:                 +/-(0.1%+2d)
  APPA 305
  Range:
                                   40.00mV~1000V
  Basic Accuracy:                 +/-(0.06%+2d)
  
  Input Impedance:                10M?
  
  APPA 201, 203, 205
  Overload Protection:
           600V DC or 600V rms
  APPA 207
  Overload Protection:
         1000V DC or 750V rms

 Resistance  
  APPA 201
  Range:                                   200.0?~20.00M?
  Basic Accuracy:                 +/-(0.8%+2d)
  APPA 203
  Range:                                   400.0?~40.00M?
  Basic Accuracy:                 +/-(0.6%+4d)
  APPA 205
  Range:                                   400.0?~40.00M?
  Basic Accuracy:                 +/-(0.4%+4d)

  APPA 207
  Range:
                                   400.0?~40.00M?
  Basic Accuracy:                 +/-(0.3%+2d)

  Overload Protection:         600V rms

 LV Resistance   
 
 APPA 207
  Range:
                                   400.0?~40.00M?
  Basic Accuracy:                 +/-(0.3%+2d)

  Overload Protection:         600V rms

 Current AC
  APPA 201
  Range:                                   200.0uA~10A
  Basic Accuracy:                 +/-(1.5%+5d)
  APPA 203
  Range:                                   4.000mA~10A
  Basic Accuracy:                 +/-(1.3%+5d)
  APPA 205
  Range:                                   4.000mA~10A
  Basic Accuracy:                 +/-(1.0%+5d)

  APPA 207
  Range:
                                   40.00mA~10A
  Basic Accuracy:                 +/-(0.8%+8d)

  APPA 201, 203
  Conversion Type:                Average sensing RMS indicating
  APPA 205
  Conversion Type:                True RMS reading on AC mode
  APPA 207
  Conversion Type:               (AC+DC) True RMS reading on AC mode
                                                  ACV spec. +1.00%+8d

  APPA 201
  Frequency Resonse:
         40Hz~500Hz
  APPA 203, 205
  Frequency Response:      
40Hz~1kHz
  APPA 207
  Frequency Response:
       40Hz~400Hz

  Input Protection:                 Equipped with High Energy Fuse.
                                                  1A, 600V, IR 10KV fuse for mA input
                                                  15A, 600V, IR 100KV fuse for A input

 Current DC  
  APPA 201
  Range:                                   200.0uA~10A
  Basic Accuracy:                 +/-(0.8%+2d)
  APPA 203
  Range:                                   4.000mA~10A
  Basic Accuracy:                 +/-(0.7%+2d)
  APPA 205
  Range:                                   4.000mA~10A
  Basic Accuracy:                 +/-(0.4%+2d)

  APPA 207
  Range:
                                   40.00mA~10A
  Basic Accuracy:                 +/-(0.2%+4d)
 
  Input Protection:                 Equipped with High Energy Fuse.
                                                  1A, 600V, IR 10KV fuse for mA input
                                                  15A, 600V, IR 100KV fuse for A input
 Continuity Beeper
  
<50?, 2k Hz tone buzzer

 Diode Test


  APPA 201, 207
  Open circuit voltage:
        3.3V
  APPA 203, 205
  Open circuit voltage:
        3.0V

 Frequency Counter  
  APPA 203, 205
  Range:
                                   100.0Hz~1MHz
  Basic Accuracy:                 +/-(0.1%+4d) 
  APPA 207
  Range:
                                   400Hz~4MHz
  Basic Accuracy:                 +/-(0.01%+1d)
                                                   
  Overload Protection:         600V rms

 Duty Factor  
  
APPA 207
  Range:
                                   20%~80%
  Basic Accuracy:                 +/-6d
                                                   
  Overload Protection:         600V rms

 Capacitance  
  APPA 203, 205
  Range:                                   4.000nF~40uF
  Basic Accuracy:                 +/-(1.0%+4d)
  APPA 207
  Range:                                   400.0nF~10mF
  Basic Accuracy:                 +/-(0.9%+20d)
  
  Overload Protection:         600V rms

 Temperature  
  APPA 207
  Range:
                                   -200?~1200?
  Basic Accuracy:                 +/-(1?+1d) at -50?~1200?

  Overload Protection          600V rms

 
 General Specifications  
 Display  
  APPA 201
  2000 count display
  APPA 203, 205
  4000 count display, 42 segment bargraph
  APPA 207
  40000/4000 count display, 80 segment bargraph

 
 Sampling Rate  
  APPA 201, 203, 205
  2times/sec
  APPA 207
 
2times/sec for 40000 count, 4times/sec for 4000 count, and 20times/ 
  sec for analog bargraph

 Overload Indication   
  APPA 201
  "1" Blinks
  APPA 203, 205
  MSD (Most Signicant Digit) Blinks
  APPA 207
  "OL" or "-OL" 

 Low Battery Indication


 
 Auto Power Off  
  APPA 201, 203, 205
  Approx. 30 minutes
  APPA 207 
  User selectable (default:30minutes)

 Operating Temperature  
 
-20?~ 50?, <80% RH 

 Storage Temperature  
 
-20?~ 60?

 Temperature Coefficient  
 
0.15(Spec. Acc)/?, <18? or >28? 

 Safety
 
IEC61010 and designed to meet UL61010 specifications 
  APPA 201, 203, 205
  CAT. II 600V
  APPA 207
  CAT. III 600V, CAT. II 1000V

 Power Requirement  
  AC 90V to 264V, 50/60Hz, 10VA min. (User supplied) DC AA or LR6 or
  AM3 battery 1.5V x 6pcs

 Battery Life


  APPA 201
  1200 hours without backlight (alkaline)
  APPA 203, 205
  1800 hours without backlight (alkaline)
  APPA 207
  100 hours without backlight (alkaline)

 Size
  APPA 201, 203, 205
 
218mm (W) x 195mm (L) x 73mm (H)
  APPA 207
  230mm (W) x 233mm (L) x 96mm (H)

 Weight  
  APPA 201, 203, 205
  1.3kg
  APPA 207
  1.7kg

 Included with Instrument  
  Safety-designed test leads, test clips, Instruction manual, 
  Carrying Strap, Power Cord, a temperature adaptor (for APPA 207),
  A K type bead sensor (for APPA 207), a RS-232 cable (for APPA 207)