Product Line

APPA 200 Series
APPA 208B APPA 200 SERIES VERSAMETERS

APPA 208B

APPA 200 SERIES VERSAMETERS

Description
.40,000 count digital display and 43 segment analog display
.Large white LED backlight display
.Dual display
.AC, DC and AC+DC on Voltage & Current mode with Frequency indication
.0.03% DCV accuracy
.40M Ohms Resistance capability
.True RMS reading on AC and AC+DC mode
.Auto Store up to 100 memories
.Data Logging up to 40,000 records
.BlueTooth(Ver. 4.0, 208B only)
.Auto Calibration
.On-Screen-Menu Selection
.LoZ for prevent false reading from ghost voltage
.Auto Fuse Detector
.High Frequency Rejection (LPF)
.Min/Max/Avg
.Relative/% Function
.Auto Hold/Peak Hold
.11A/1000V & 400mA/1000V High Energy Fuses
.dBm/dB measurement
.Store/Recall memories
.Virtual Instrumentation
.USB interface with Software included
.Temperature Probe included
.Test lead storage compartment
.Side & neck strap design for handle carrying
.Power Line 110V, 220V Selectable
.CAT III 600V/CAT II 1000V standard
View More Details
APPA 200 Series
Features

  APPA 201N APPA 208 APPA 208B
Digital display 2000 count 4000/40000 count 4000/40000 count
Analog Bar graph Segments N/A 43 43
Autoranging and Manual selection v v v
AC+DC True RMS  AC only v v
Auto Calibration N/A v v
Backlit v v v
Automatic AC/DC voltage detector with low impedance(Auto-V LoZ) N/A v v
High Frequency Rejection (HFR) N/A v v
Peak Hold N/A v v
Auto Hold v v v
MIN/MAX v v v
Relative Mode N/A v v
Duty Cycle N/A v v
Memory Store/Recall  N/A 1000 1000
dBm/dB reading N/A v v
Data Logging Capacity N/A 40,000 40,000
Optical interface N/A v v
Bluetooth N/A N/A v
Auto fuse detection N/A v v
Beep Guard N/A v v
Low Battery Indication v v v

SPECIFICATIONS:(All at 23°C±5°C, ≦ 80% R.H.)
    APPA 201N APPA 208 APPA 208B
DCV: Ranges 200mV to 600V 40mV to 1000V 40mV to 1000V
  Resolution 100uV 1uV 1uV
  Basic Accuracy ±(0.5%+2d) ±(0.03%+10d) ±(0.03%+10d)
ACV: Ranges 200mV to 600V 40mV to 1000V 40mV to 1000V
  Resolution 100uV 1uV 1uV
  Basic Accuracy ±(1.5%+5d) ±(0.5%+20d) ±(0.5%+20d)
  Bandwidth 50Hz to 500Hz 40Hz to 100kHz 40Hz to 100kHz
(AC+DC)V: Ranges & Resolution:Same as ACV, except Accuracy N/A v v
Auto V-LoZ Range: 400.0V, 1000V N/A v v
DCA: Ranges 200uA to 10A 40mA to 10A 40mA to 10A
  Resolution 0.1uA 1uA 1uA
  Basic Accuracy ±(1.0%+2d) ±(0.2%+10d) ±(0.2%+10d)
ACA: Ranges 200uA to 10A 40mA to 10A 40mA to 10A
  Resolution 0.1uA 1uA 1uA
  Basic Accuracy ±(1.5%+5d) ±(0.8%+20d) ±(0.8%+20d)
  Bandwidth 50Hz to 500Hz 40Hz to 10KHz 40Hz to 10KHz
(AC+DC)A: Ranges & Resolution:Same as ACA, except Accuracy N/A v v
OHM: Ranges 200Ω to 20MΩ 400Ω to 40MΩ 400Ω to 40MΩ
  Resolution 0.1Ω 0.01Ω 0.01Ω
  Basic Accuracy ±(0.7%+3d) ±(0.2%+10d) ±(0.2%+10d)
Continuity: 2kHz Tone Buzzer <50Ω 10Ω~50Ω(Adj) 10Ω~50Ω(Adj)
Diode Test: Open Circuit Voltage ±3V ±2.5V ±2.5V
Frequency Counter: Ranges 2000Hz to 20MHz 40Hz to 4MHz 40Hz to 4MHz
  Resolution 1Hz 0.001Hz 0.001Hz
  Basic Accuracy ±(0.01%+2d) ±5d ±5d
Duty Factor: Ranges N/A 5% to 95% 5% to 95%
  Resolution N/A 0.1% 0.1%
  Basic Accuracy:5Hz to 10kHz, 5Vp-p N/A ±3d ±3d
Capacitance: Ranges 2nF to 2mF 40nF to 40mF 40nF to 40mF
  Resolution 1pF 10pF 10pF
  Basic Accuracy ±(1.9%+8d) ±(0.9%+2d) ±(0.9%+2d)
℃ / ℉ Ranges N/A -200℃ to 1200℃ -200℃ to 1200℃
  Resolution: N/A 0.1℃ 0.1℃
  Basic Accuracy: N/A ±(1%+10d) for ℃ ±(1%+10d) for ℃

GENERAL:
  APPA 201N APPA 208 APPA 208B
Analog bargraph display: N/A v v
Measuring Rate:  1.5 times/sec 10 times/sec 10 times/sec
Over range Indication : OL OL OL
Auto Power Off :  10 minutes 1~30 minutes(Adj) 1~30 minutes(Adj)
Operating Temperature : 0℃~50℃, ≦80%RH v v v
Storage Temperature : -20℃~60℃ v v v
Temperature Coefficient : 0.1 x (Spec.Acc)/℃, <18℃ or >28℃ v v v
Safety : IEC 1010-1 CAT III 300V, CAT II 600V CAT III 600V, CAT II 1000V CAT III 600V, CAT II 1000V
EMC: EN61326-1 N/A v v
Power Requirement:AC 100~ 240V, 50/60Hz, 10VA  v v v
                                         DC AA or LR6 or AM3 battery 1.5V x 6 v v v
Battery Life:In hours without backlight (Alkaline battery) 1200 50 50
Size: without carrying case (mm) 218(W) x 195(L) x 73(H) 230(W) x 233(L) x 95(H) 230(W) x 233(L) x 95(H)
Weight:without power cord  1.3Kg 1.6Kg 1.6Kg
Accessories:Test Leads, carrying strap, power cord and manual v (also including Temp. probe, USB cable and APPA WinDMM 208 software)  (also including Temp. probe, USB cable and APPA WinDMM 208 software) 

Specification subject to change without notice.

  • Designed for using in a laboratory

  • Designed for harsh environment

  • Extra back storage for full accessories

  • Handle carrying design for mobility

relevant information