Product Line

Product Line
APPA 138F APPA 130F SERIES CLAMP MULTIMETERS

APPA 138F

APPA 130F SERIES CLAMP MULTIMETERS

Description
.10,000 Count digital display
.Active Backlit, Large scale display
.Analog Bar graph
.True RMS reading on AC and AC+DC mode
.Torch lightening when clamping
.Auto AC/DC 1000 Amps capability and selection
.Auto AC/DC 1000 Volts capability and selection
.Auto Ohms/Continuity/Diode selection
.Power and Power factor Measurement
.Total Harmonics Distortion and Harmonics 1 to 25
.Phase Rotation Indication
.100K Ohms Resistance capability
.VoltSenseTM (None Contact Voltage)
.Continuity Beeper
.Frequency Counter
.Capacitance capability
.°C/°F Temperature Function
.Smart Data Hold
.Peak Hold
.Inrush Current
.DCA Auto-Zeroing Key
.Min Max Hold
.Low Pass Filter
.Auto Power Off
.Up to 42mm dia. (1000MCM) Conductor
.Bus bar size 62mm x 12mm
.4 feet Drop Proof
.Temperature probe included
.Deluxe Carrying Case
.Hand Guard & Stream Line Designed
.Convenient Battery Door
.CAT. IV 600V /CAT. III 1000V Safety Standard
View More Details
APPA 130F Series (1.4 MB)
Features
  APPA 133F APPA 136F APPA 137F APPA 138F
Digital display 10000 count 10000 count 10000 count 10000 count
Analog bar graph 60 segments 60 segments 60 segments 60 segments
True RMS measuring AC+DC AC+DC AC+DC AC+DC
Auto AC/DC detection v v v v
Smart Data hold v v v v
Min/Max function v v v v
Peak hold v v v v
Inrush Current measurement v v v v
DCA zeroing  NA NA v NA
Low Pass Filter v v v v
Frequency counter v v v v
Power and Power Factor measurement v v v v
Total Harmonic Distortion v v v v
Phase Rotation v v v v
Temperature measurement NA v NA NA
Capacitance v v v v
Audible continuity and Diode test v v v v
Backlight v v v v
Torch Lighting v v v v
VoltSenseTM (None Contact Voltage) v v v v
Automatic power shut off v v v v
Shock proof from 4 feet drops v v v v
Standard full-sleeve safety test leads v v v v
Deluxe carrying case v v v v

SPECIFICATIONS:(All at 23°C±5°C, ≦ 80% R.H.)
    APPA 133F APPA 136F APPA 137F APPA 138F
ACA: Ranges 100.00A, 600.0A 100.00A, 600.0A 100.00A, 1000.0A 100.00A, 1000.0A
  Resolution 0.01A 0.01A 0.01A 0.01A
  Basic Accuracy:  ±(1.5%+5d) at 50Hz~60Hz                          ±(2.0%+5d) at 61Hz~400Hz ±(1.5%+5d) at 50Hz~60Hz                          ±(2.0%+5d) at 61Hz~400Hz ±(1.5%+5d) at 50Hz~60Hz                          ±(2.0%+5d) at 61Hz~400Hz ±(1.5%+5d) at 50Hz~60Hz                          ±(2.0%+5d) at 61Hz~400Hz
  Conversion Type: Average sensing RMS indicating AC+DC True-RMS AC+DC True-RMS AC+DC True-RMS AC+DC True-RMS
  Inrush Current Basic Accuracy: ±(2.5%+5d) ±(2.5%+5d) ±(2.5%+5d) ±(2.5%+5d)
DCA: Ranges  NA 100.00A, 600.0A NA 100.00A, 1000.0A
  Resolution 0.01A 0.01A
  Basic Accuracy ±(1.5%+5d) ±(1.5%+5d)
AC Current via SFLEX-T Ranges   0.1A~3000A 0.1A~3000A 0.1A~3000A 0.1A~3000A
AC+DC A: Ranges  NA 100.00A, 600.0A NA 100.00A, 1000.0A
  Resolution 0.01A 0.01A
  Basic Accuracy Same as ACA +(1.5%+5d) Same as ACA +(1.5%+5d)
ACV: Ranges 100.00V~1000V 100.00V~1000V 100.00V~1000V 100.00V~1000V
  Resolution 0.01V 0.01V 0.01V 0.01V
  Basic Accuracy: ±(1.0%+5d) at 50Hz~500Hz v v v v
  Input Impedance: 3.5MΩ // <100pF v v v v
  Overload Protection: 1000V rms v v v v
  Conversion Type: Average sensing RMS indicating AC+DC True-RMS AC+DC True-RMS AC+DC True-RMS AC+DC True-RMS
DCV: Ranges 100.00V~1000V 100.00V~1000V 100.00V~1000V 100.00V~1000V
  Resolution 0.01V 0.01V 0.01V 0.01V
  Basic Accuracy ±(0.7%+2d) ±(0.7%+2d) ±(0.7%+2d) ±(0.7%+2d)
  Input Impedance: 3.5MΩ v v v v
  Overload Protection: 1000V rms v v v v
AC+DC V: Ranges 100.00V~1000V 100.00V~1000V 100.00V~1000V 100.00V~1000V
  Resolution 0.01V 0.01V 0.01V 0.01V
  Basic Accuracy  ±(1.0%+5d)  ±(1.0%+5d)  ±(1.0%+5d)  ±(1.0%+5d)
  Input Impedance: 3.5MΩ v v v v
  Overload Protection: 1000V rms v v v v
Watt: Ranges 10KW~600KW 10KW~600KW 10KW~1MW 10KW~1MW
  Resolution 1W 1W 1W 1W
  Basic Accuracy ±(2.5%+5d) ±(2.5%+5d) ±(2.5%+5d) ±(2.5%+5d)
P.F.: Ranges -1.00~1.00 -1.00~1.00 -1.00~1.00 -1.00~1.00
  Resolution 0.01 0.01 0.01 0.01
  Basic Accuracy  ±3°  ±3°  ±3°  ±3°
T.H.D.: Ranges 0.1%~100.0% 0.1%~100.0% 0.1%~100.0% 0.1%~100.0%
  Resolution 0.1% 0.1% 0.1% 0.1%
  Basic Accuracy ±(3.0%+10d) ±(3.0%+10d) ±(3.0%+10d) ±(3.0%+10d)
Harmonics: Ranges 0.1%~100.0% 0.1%~100.0% 0.1%~100.0% 0.1%~100.0%
  Resolution 0.1% 0.1% 0.1% 0.1%
  Basic Accuracy: ±(5.0%+10d) for order 1-12,
±(10.0%+10d) for order 13-25
v v v v
OHM: Ranges 1.0000KΩ, 10.00KΩ, 100.00KΩ 1.0000KΩ, 10.00KΩ, 100.00KΩ 1.0000KΩ, 10.00KΩ, 100.00KΩ 1.0000KΩ, 10.00KΩ, 100.00KΩ
  Resolution 0.01Ω 0.01Ω 0.01Ω 0.01Ω
  Accuracy ±( 1.0%+3d) ±( 1.0%+3d) ±( 1.0%+3d) ±( 1.0%+3d)
  Overload Protection: 1000V rms v v v v
Continuity Beeper:  <30Ω, 2KHz tone buzzer v v v v
Diode Test: Open circuit voltage: ±1.8V max v v v v
Capacitance Ranges 400.0μF, 4.000mF 400.0μF, 4.000mF 400.0μF, 4.000mF 400.0μF, 4.000mF
  Resolution 0.1μF 0.1μF 0.1μF 0.1μF
  Basic Accuracy  ±(1.9%+8d)  ±(1.9%+8d)  ±(1.9%+8d)  ±(1.9%+8d)
  Overload Protection: 1000V rms v v v v
Frequency Counter:  Ranges 20.0Hz~10KHz 20.0Hz~10KHz 20.0Hz~10KHz 20.0Hz~10KHz
  Resolution 0.1Hz 0.1Hz 0.1Hz 0.1Hz
  Basic Accuracy ±(0.5%+3d) ±(0.5%+3d) ±(0.5%+3d) ±(0.5%+3d)
  Overload Protection: AC/DC 600A v v    
                                    AC/DC 1000A     v v
Temperature: Ranges NA NA NA     -50°C~1000°C/
-58°F~1832°F
  Resolution 0.1°C/0.1°F
  Accuracy ±(1%+1°C)/±(1%+2°F)
  Overload Protection: 1000V rms v

GENERAL:
  APPA 133F APPA 136F APPA 137F APPA 138F
Sampling Rate  3times/sec 3times/sec 3times/sec 3times/sec
Overload Indication  "OL" or "-OL" "OL" or "-OL" "OL" or "-OL" "OL" or "-OL"
Low Battery Indication
Auto Power Off: Approx. 15 minutes v v v v
Operating Temperature: 0°C~50°C, ≦80% RH v v v v
Storage Temperature: - 20°C ~ 60°C v v v v
Temperature Coefficient: 0.2(Spec. Acc)/°C, <18°C or>28°C v v v v
Safety: IEC 61010 and designed to meet UL61010 specifications CAT. IV 600V CAT. III 1000V CAT. IV 600V CAT. III 1000V CAT. IV 600V  CAT. III 1000V CAT. IV 600V CAT. III 1000V
Maximum Conductor Size 37mm dia. (750MCM) 37mm dia. (750MCM) 42mm dia. (1000MCM) 42mm dia. (1000MCM)
Maximum Jaw Opening 45mm 45mm 45mm 45mm
Maximum Busbar Size 45x10mm 45x10mm 62x12mm 62x12mm
Power Requirement: Single 9V battery (NEDA 1604 or IEC 6F22) v v v v
Battery Life: In hours (Alkaline battery、Without Backlight) 50 50 50 50
Size: 87.5mm(W) x 242mm(L) x 50.5mm(H) v v    
         87.5mm(W) x 257mm(L) x 50.5mm(H)     v v
Weight: In grams  435 435 470 470
Included with instrument: Test Leads, ZnC battery (installed)  manual and carrying case v v v (also including Temperature Probe)

Specification subject to change without notice.

AUTOMATIC SELECTION

Automatically detect AC, DC and AC+DC of Ampere and Voltage function with AC+DC True RMS, and automatically selection of resistance, continuity and diode.

ACTIVE BACKLIT

APPA 130F series Pro clamp meters all have an active backlit display that turns ON at the touch of a button or rotate the knob, also automatically goes off to save battery life.

INNOVATIVE LIGHTENING AND LIVE VOLTAGE SENSIN

Torch lightening during cable clamping and automatically non contact voltage detection for better identification of working environment.

FLEXIBLE CURRENT TEST

APPA 130F series integrated with SFLEX-T flexible current probe expanding the current range to 3,000 ACA, providing increased display flexibility, making electrical measurement easier and safer.

ADVANCED POWER FEATURES MADE EASY

Every APPA 130F series Pro clamp meter provides advanced Power features, Phase rotation, Total Harmonics Distortion and even Harmonics 1 to 25th with easy-to-use interface, which enables fully professional power measurement application with excellent performance.

INNOVATIVE NAVIGATOR

Innovative designed navigator key optimized the function selection and feature operation with a finger of thumb.
Loading...
History
    3Inquiry